MantisBT - ParaView
View Issue Details
0004087ParaView(No Category)public2006-11-27 18:462006-12-18 19:14
Ken Moreland 
Clinton Stimpson 
urgentminoralways
closedfixed 
 
 
0004087: X,Y,Z Normal buttons not updating widget GUI
In the GUI for the clip and cut filters, the "X Normal", "Y Normal", and "Z Normal" buttons do not have an immediate effect on either the 3D widget or the "Normal" 2D GUI entries.

Internally, these buttons must set SM properties, because the selected normal is used if "Accept" is hit. Also, if you change the camera, the 3D widget is updated to the new normal (but the 2D widgets never are).
No tags attached.
Issue History
2011-06-16 13:10Zack GalbreathCategory => (No Category)

Notes
(0005925)
Clinton Stimpson   
2006-12-08 14:05   
/cvsroot/ParaView3/ParaView3/Qt/Components/pqImplicitPlaneWidget.cxx,v <-- pqImplicitPlaneWidget.cxx
new revision: 1.11; previous revision: 1.10