Summary0011191: isovolume wrong for cth amr point data
DescriptionParaView trunk, local server, Windows.
Open the spcta_a.[0-3] dataset.
Cell to Point filter.
isoVolume.
Bug - notice that the object is hollow, and has bad normals (bad lighting).

This needs to be fixed for 3.10.
TagsNo tags attached.
Project
Topic Name
Type
Attached Files

 Relationships

  Notes
(0036424)
Alan Scott (manager)
2016-07-13 18:21

Changing to backlog. This is still a bug.

The root cause of the problem is that the Iso Volume filter is keeping data from equal to or greater than a min, and less than (but not equal to a max.) We need to make it less than or equal to max.
(0037876)
Kitware Robot (administrator)
2016-08-12 09:58

Resolving issue as `moved`.

This issue tracker is no longer used. Further discussion of this issue may take place in the current ParaView Issues page linked in the banner at the top of this page.

 Issue History
Date Modified Username Field Change
2010-08-30 20:47 Alan Scott New Issue
2010-11-09 09:42 Utkarsh Ayachit Target Version 3.10 => 3.10.shortlist
2016-07-13 18:21 Alan Scott Assigned To => Alan Scott
2016-07-13 18:21 Alan Scott Note Added: 0036424
2016-07-13 18:21 Alan Scott Status expired => backlog
2016-07-13 18:21 Alan Scott Resolution open => reopened
2016-07-13 19:06 Alan Scott Assigned To Alan Scott =>
2016-08-12 09:58 Kitware Robot Note Added: 0037876
2016-08-12 09:58 Kitware Robot Status backlog => closed
2016-08-12 09:58 Kitware Robot Resolution reopened => moved
2016-08-12 09:58 Kitware Robot Assigned To => Kitware Robot