View Issue Details Jump to Notes ] Print ]
IDProjectCategoryView StatusDate SubmittedLast Update
0004460ParaView(No Category)public2007-02-13 18:442007-04-02 17:00
ReporterKen Moreland 
Assigned ToUtkarsh Ayachit 
PriorityhighSeveritymajorReproducibilityalways
StatusclosedResolutionfixed 
PlatformOSOS Version
Product Version 
Target VersionFixed in Version 
Summary0004460: No histogram for constant variable
DescriptionWhen a variable is constant, the histogram filter returns nothing.

Although on the surface it makes little sense to make a histogram when all the values are the same, the user might not know that a-priori. We can solve the problem by artifically expanding the limits of variables slightly and placing all of the values in a single bin.
TagsNo tags attached.
Project
Topic Name
Type
Attached Files

 Relationships

  Notes
(0006425)
Ken Moreland (manager)
2007-02-15 12:08

Added a lable to the ExtractHistogram filter.

/cvsroot/ParaView3/ParaView3/Servers/ServerManager/Resources/filters.xml,v <-- filters.xml
new revision: 1.176; previous revision: 1.175
(0006454)
Ken Moreland (manager)
2007-02-15 19:17

Oops. I just closed the wrong bug. Ignore the last entry.
(0006894)
Utkarsh Ayachit (administrator)
2007-03-21 18:25

Fixed by pretending the data range is 1 when range is 0.

/cvsroot/ParaView3/ParaView3/Servers/Filters/vtkExtractHistogram.cxx,v <-- vtkExtractHistogram.cxx
new revision: 1.16; previous revision: 1.15

 Issue History
Date Modified Username Field Change
2011-06-16 13:10 Zack Galbreath Category => (No Category)