0010864: Setting for interactive rendering delay
Thanks to the resolution of 0010232, there is a two second pause from the time you start interacting and the time a still render starts. (Awesome feature, BTW.) There should also be a settings option (under Render View -> General) that allows you to set the length of this pause. If set down to 0, then there would be no pause (i.e. the old behavior).

I don't know what the maximum wait should be. 5 sec? 10? 30?
No tags attached.
related to 0010232closed Utkarsh Ayachit Improve usability of LOD actors 
has duplicate 0011100closed Ken Moreland LOD delay should be configurable 
Issue History
2010-06-22 11:37Ken MorelandNew Issue
2010-06-22 11:37Ken MorelandRelationship addedrelated to 0010232
2010-06-22 11:38Ken MorelandTarget Version => 3.10
2010-06-22 11:38Ken MorelandStatusbacklog => tabled
2010-06-22 11:38Ken MorelandAssigned To => Utkarsh Ayachit
2010-08-05 20:37Ken MorelandRelationship addedhas duplicate 0011100
2011-06-16 13:10Zack GalbreathCategoryFeature Request => Feature
2013-10-17 17:35Alan ScottNote Added: 0031693
2013-10-17 17:35Alan ScottStatusexpired => closed
2013-10-17 17:36Alan ScottResolutionopen => fixed

Notes
(0031693)
Alan Scott   
2013-10-17 17:35   