View Issue Details Jump to Notes ] Print ]
IDProjectCategoryView StatusDate SubmittedLast Update
0006146ParaView(No Category)public2007-12-11 10:092008-03-07 07:56
ReporterDavid Karelitz 
Assigned To 
PrioritynormalSeveritymajorReproducibilityalways
StatusclosedResolutionfixed 
PlatformOSOS Version
Product Version 
Target VersionFixed in Version 
Summary0006146: (MARS-normal) Calculator causes upstream filters/readers to re-execute
DescriptionWhen you apply a calculator filter (after accepting the changes from any upstream filters), the calculator causes all the upstream filters to re-execute. This may be related to the bug about issues when the first timestep in a file is not 0, but I'm not positive
TagsNo tags attached.
Project
Topic Name
Type
Attached Files

 Relationships

  Notes
(0009859)
David Karelitz (reporter)
2007-12-11 12:29

The problem seems to be with CellToPoint. Just about anything causes it to re-execute.
(0010181)
David Karelitz (reporter)
2008-01-17 17:54

This doesn't look like a bug anymore. It seems like it was related to compute normals on contour causing ghost cells to be needed.

 Issue History
Date Modified Username Field Change
2007-12-11 10:09 David Karelitz New Issue
2007-12-11 12:29 David Karelitz Note Added: 0009859
2008-01-17 17:54 David Karelitz Status backlog => closed
2008-01-17 17:54 David Karelitz Note Added: 0010181
2008-01-17 17:54 David Karelitz Resolution open => fixed
2008-03-07 07:56 Berk Geveci Target Version => MARS
2011-06-16 13:10 Zack Galbreath Category => (No Category)


Copyright © 2000 - 2018 MantisBT Team